  • 3G2.5 H07RN-F (2C+E 2.5mm)

    3G2.5 H07RN-F (2C+E 2.5mm)

    Rubber, power and control cable. Class 5 tinned copper conductors, colour or number coded ethylene-propylene rubber insulating material, flame-retardant, UV, ozone and oil-resistant black rubber sheath.

  • 3G25 H07RN-F (2C+E 25mm)

    3G25 H07RN-F (2C+E 25mm)

    Rubber, power and control cable. Class 5 tinned copper conductors, colour or number coded ethylene-propylene rubber insulating material, flame-retardant, UV, ozone and oil-resistant black rubber sheath.

  • 3G4 H07RN-F (2C+E 4mm)

    3G4 H07RN-F (2C+E 4mm)

    Rubber, power and control cable. Class 5 tinned copper conductors, colour or number coded ethylene-propylene rubber insulating material, flame-retardant, UV, ozone and oil-resistant black rubber sheath.

  • 3G6 H07RN-F (2C+E 6mm)

    3G6 H07RN-F (2C+E 6mm)

    Rubber, power and control cable. Class 5 tinned copper conductors, colour or number coded ethylene-propylene rubber insulating material, flame-retardant, UV, ozone and oil-resistant black rubber sheath.

  • 3x35 Type 241.1

    3×35 Type 241.1

    Type 241.1 Reeling and Trailing cable. Class 5 tinned and annealed copper wires. Power, earth and pilot conductors comply with AS/NZS 1125:2001 and AS/NZS 1802:2003. Crush-resistant central cradle construction, flexible Ethylene Propylene Rubber (EPR) insulation, reinforced Radial-strengthened heavy duty jacket, oil-resistant and flame retardant.

  • 3x50 Type 241.1

    3×50 Type 241.1

    Type 241.1 Reeling and Trailing cable. Class 5 tinned and annealed copper wires. Power, earth and pilot conductors comply with AS/NZS 1125:2001 and AS/NZS 1802:2003. Crush-resistant central cradle construction, flexible Ethylene Propylene Rubber (EPR) insulation, reinforced Radial-strengthened heavy duty jacket, oil-resistant and flame retardant.

  • 3x6 Type 241.1

    3×6 Type 241.1

    Type 241.1 Reeling and Trailing cable. Class 5 tinned and annealed copper wires. Power, earth and pilot conductors comply with AS/NZS 1125:2001 and AS/NZS 1802:2003. Crush-resistant central cradle construction, flexible Ethylene Propylene Rubber (EPR) insulation, reinforced Radial-strengthened heavy duty jacket, oil-resistant and flame retardant.

  • 4mm 2 Core + Earth Orange CIRC 0.6/1Kv

    4mm 2 Core + Earth Orange CIRC 0.6/1Kv

    Class 2 stranding, white with black numbering PVC insulation, flame retardant, UV resistant orange PVC sheath

  • 4pr 0.5mm Ind & Overall Scr Inst Cable

    4pr 0.5mm Ind & Overall Scr Inst Cable

    High temperature PVC V90HT overall and individually screened. Class 2 stranding, twisted pairs with heat resistant PVC V90HT insulation, aluminium polyester tape individual pair screen, overall aluminium polyester tape screen with 0.5mm² tinned copper drain wire, heat & UV resistant, flame retardant, black PVC V90HT sheath. Also available in an intrinsically blue sheath upon request.

  • 4pr 0.5mm Overall Scr Inst Cable Black

    4pr 0.5mm Overall Scr Inst Cable Black

    RALOS instrumentation cables are manufactured to the requirement of BS50288 as well as relevant Australia standard. Suitable for the interconnection of control equipment and instrument.

  • 4pr 1.5mm Ind & Overall Scr Inst Cable

    4pr 1.5mm Ind & Overall Scr Inst Cable

    High temperature PVC V90HT overall and individually screened. Class 2 stranding, twisted pairs with heat resistant PVC V90HT insulation, aluminium polyester tape individual pair screen, overall aluminium polyester tape screen with 0.5mm² tinned copper drain wire, heat & UV resistant, flame retardant, black PVC V90HT sheath. Also available in an intrinsically blue sheath upon request.

  • 4pr 1.5mm Overall Scr Inst Cable Black

    4pr 1.5mm Overall Scr Inst Cable Black

    RALOS instrumentation cables are manufactured to the requirement of BS50288 as well as relevant Australia standard. Suitable for the interconnection of control equipment and instrument.

  • 6mm 2 Core + Earth Orange CIRC 0.6/1Kv

    6mm 2 Core + Earth Orange CIRC 0.6/1Kv

    Class 2 stranding, white with black numbering PVC insulation, flame retardant, UV resistant orange PVC sheath

  • 6pr 0.5mm Ind & Overall Scr Inst Cable

    6pr 0.5mm Ind & Overall Scr Inst Cable

    High temperature PVC V90HT overall and individually screened. Class 2 stranding, twisted pairs with heat resistant PVC V90HT insulation, aluminium polyester tape individual pair screen, overall aluminium polyester tape screen with 0.5mm² tinned copper drain wire, heat & UV resistant, flame retardant, black PVC V90HT sheath. Also available in an intrinsically blue sheath upon request.

  • 6pr 0.5mm Overall Scr Inst Cable Black

    6pr 0.5mm Overall Scr Inst Cable Black

    RALOS instrumentation cables are manufactured to the requirement of BS50288 as well as relevant Australia standard. Suitable for the interconnection of control equipment and instrument.

  • 6pr 1.5mm Ind & Overall Scr Inst Cable

    6pr 1.5mm Ind & Overall Scr Inst Cable

    High temperature PVC V90HT overall and individually screened. Class 2 stranding, twisted pairs with heat resistant PVC V90HT insulation, aluminium polyester tape individual pair screen, overall aluminium polyester tape screen with 0.5mm² tinned copper drain wire, heat & UV resistant, flame retardant, black PVC V90HT sheath. Also available in an intrinsically blue sheath upon request.